COMANDO E CONTROLLO PROTEZIONE (LPL) DEL SISTEMA DI PROTEZIONE ILLUMINAZIONE ESTERNA (QUALSIASI LIVELLO KERAUNICO)? LPL III/IV LPL I/II Alloggio terziario-industriale-collettivo N° di poli "Abitazione/ casa" Alloggio terziario-industriale-collettivo Quadro principale Quadro di distribuzione Quadro principale Quadro di distribuzione T1+T2 Iimp 12,5 kA T2 Imax 20 kA T1+T2 Iimp 12,5 kA T1+T2 Iimp 25 kA T2 Imax 40 kA F10MB1 F10AB1 1P F10MB1 F10VX1 (Iimp 35 kA) F10HB1 F10MB2 F10AB2 2P F10MB2 - F10HB2 F10MC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) 1P+N F10MC2 (Si) - F101HZC2(1) (Isc ≤ 25 kA) F10HS2/F10HC2 (Si) F10MB1 x 3 F10AB1 x 3 3P F10MB1 x 3 F10VX1 x 3 F10HB1 x 3 F10MB4 F10AB4 4P F10MB4 - F10HB4 F10MC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) 3P+N F10MC4 (Si) F10T4 F101HZC4(1) (Isc ≤ 25 kA) F10HS4/F10HC4 (Si) ATTIVITÀ DEL TEMPORALE: BASSO LIVELLO MEDIO DI ATTIVITA DEL TEMPORALE: STANDARD LIVELLO MEDIO DI ATTIVITA DEL TEMPORALE: ALTO LPL III/IV LPL I/II LPL I/II Alloggio terziario-industriale-collettivo N° di poli "Abitazione/ casa" Alloggio terziario-industriale-collettivo N° di poli "Abitazione/ casa" Alloggio terziario-industriale-collettivo Quadro principale Quadro di distribuzione Quadro principale Quadro di distribuzione Quadro principale Quadro di distribuzione T2 Imax 40 kA T2+T3 Imax 10 kA T2+T3 Imax 10 kA T2 Imax 40 kA T2 Imax 20 kA T2+T3 Imax 10 kA T1+T2 Imax 12,5 kA T2 Imax 20 kA F10HB1 - 1P - F10HB1 F10AB1 1P - F10MB1 F10AB1 F10HB2 - 2P - F10HB2 F10AB2 2P - F10MB2 F10AB2 F101HZC2(1) (Isc ≤ 25 kA) F10HS2/F10HC2 (Si) F10AP2(2) (Isc 6 kA) 1P+N F10AP2(2) (Isc 6 kA) F101HZC2(1) (Isc ≤ 25 kA) F10HS2/F10HC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) 1P+N F10AP2(2) (Isc 6 kA) F10MC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) F10HB1 x 3 - 3P - F10HB1 x 3 F10AB1 x 3 3P - F10MB1 x 3 F10AB1 x 3 F10HB4 - 4P - F10HB4 F10AB4 4P - F10MB4 F10AB4 F101HZC4(1) (Isc ≤ 25 kA) F10HS4/F10HC4 (Si) F10HP4(2) (Isc 10 kA) Neutro a sinistra 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F101HZC4(1) (Isc ≤ 25 kA) F10HS4/F10HC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F10MC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) T1+T2 Imax 12,5 kA T2 Imax 20 kA T2+T3 Imax 10 kA T1+T2 Imax 12,5 kA T2 Imax 20 kA T2+T3 Imax 10 kA T1+T2 Iimp 12,5 kA T2 Imax 20 kA F10MB1 F10AB1 1P - F10MB1 F10AB1 1P - F10MB1 F10AB1 F10MB2 F10AB2 2P - F10MB2 F10AB2 2P - F10MB2 F10AB2 F10MC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) 1P+N F10AP2(2) (Isc 6 kA) F10MC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) 1P+N F10AP2(2) (Isc 6 kA) F10MC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) F10MB1 x 3 F10AB1 x 3 3P - F10MB1 x 3 F10AB1 x 3 3P - F10MB1 x 3 F10AB1 x 3 F10MB4 F10AB4 4P - F10MB4 F10AB4 4P - F10MB4 F10AB4 F10MC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F10MC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F10MC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) T2 Imax 20 kA T2+T3 Imax 10 kA T2+T3 Imax 10 kA T2 Imax 40 kA T2+T3 Imax 10 kA T2+T3 Imax 10 kA T2 Imax 40 kA T2 Imax 20 kA F10AB1 - 1P - F10HB1 - 1P - F10HB1 F10AB1 F10AB2 - 2P - F10HB2 - 2P - F10HB2 F10AB2 F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) F10AP2(2) (Isc 6 kA) 1P+N F10AP2(2) (Isc 6 kA) F101HZC2(1) (Isc ≤ 25 kA) F10HS2/F10HC2 (Si) F10AP2(2) (Isc 6 kA) 1P+N F10AP2(2) (Isc 6 kA) F101HZC2(1) (Isc ≤ 25 kA) F10HS2/F10HC2 (Si) F10AZC2(1) (Isc ≤ 25 kA) F10AS2/F10AC2 (Si) F10AB1 x 3 - 3P - F10HB1 x 3 - 3P - F10HB1 x 3 F10AB1 x 3 F10AB4 - 4P - F10HB4 - 4P - F10HB4 F10AB4 F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) F10HP4(2) (Isc 10 kA) Neutro a sinistra 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F101HZC4(1) (Isc ≤ 25 kA) F10HS4/F10HC4 (Si) F10HP4(2) (Isc 10 kA) Neutro a sinistra 3P+N F10HP4(2) (Isc 10 kA) Neutro a sinistra F101HZC4(1) (Isc ≤ 25 kA) F10HS4/F10HC4 (Si) F10AZC4(1) (Isc ≤ 25 kA) F10AS4/F10AC4 (Si) SCEGLIERE LA PROTEZIONE ASSOCIATA Ref. scaricatore T1 + T2 Iimp 25 kA o 35 kA T1 + T2 Iimp 12,5 kA T2 Imax 40 kA T2 Imax 20 kA Ref. interruttore MEGATIKER 160 (80 A) BTDIN 63 A curva C BTDIN 40 A curva C BTDIN 20 A curva C Tri Tetra Bi Tri Tetra Bi Tri Tetra Bi Tri Tetra Icc ≤ 10 kA - - FH82C63 FH83C63 FH84C63 FH82C40 FH83C40 FH84C40 FH82C20 FH83C20 FH84C20 Icc ≤ 16 kA T713E80 T714E80 FT82C63 FT83C63 FT84C63 FT82C40 FT83C40 FT84C40 FT82C20 FT83C20 FT84C20 Icc ≤ 25 kA T713B80 T714B80 FV82C63 FV83C63 FV84C63 FV82C40 FV83C40 FV84C40 FV82C20 FV83C20 FV84C20 Icc ≤ 36 kA - - - - - - - - - - - Icc ≤ 50 kA T713N80 T714N80 FX82C63 FX83C63 FX84C63 FX82C40 FX83C40 FX84C40 - - - 861
RkJQdWJsaXNoZXIy NjQxMjc=